Table of Contents
TorresVault Flash Array (SSD Pool)
This page documents the full SSD layout, serial numbers, physical placement, and ZFS vdev assignments for the all-flash array inside the PVE-NAS node.
This array uses 22 Γ Samsung PM863 1.92TB SSDs arranged as 11 mirrored vdevs.
π¦ Drive Inventory β Master Table
| ID | Serial Number | Model | Size | Port Mapping | Physical Location | VDEV | Role | Notes |
| ββ | βββββ- | βββ | βββ | ββββββ | ββββββββ- | βββ | βββ | βββ |
| D01 | S1YKNX0H602526 | PM863 | 1.92 TB | Tray 01 β Upper | Mirror 01 | Data | ||
| D02 | S1YKNXAGB51740 | PM863 | 1.92 TB | Tray 01 β Upper | Mirror 01 | Data | drive-scsi3 | |
| D03 | S1YKNXAH301378 | PM863 | 1.92 TB | Tray 02 β Upper | Mirror 02 | Data | drive-scsi6 | |
| D04 | S1YKNXAGB49810 | PM863 | 1.92 TB | Tray 02 β Upper | Mirror 02 | Data | ||
| D05 | S1YKNX0H602529 | PM863 | 1.92 TB | Tray 03 β Upper | Mirror 03 | Data | ||
| D06 | S1YKNXAGB55937 | PM863 | 1.92 TB | Tray 03 β Upper | Mirror 03 | Data | X | |
| D07 | bf9b | PM863 | 1.92 TB | Tray 04 β Upper | Mirror 04 | Data | ||
| D08 | 5e8c | PM863 | 1.92 TB | Tray 04 β Upper | Mirror 04 | Data | ||
| D09 | S1YKNXAH301436 | PM863 | 1.92 TB | Tray 05 β Upper | Mirror 05 | Data | x | |
| D10 | S1YKNXAGB51503 | PM863 | 1.92 TB | Tray 05 β Upper | Mirror 05 | Data | x | |
| D11 | S1YKNXAGB52794 | PM863 | 1.92 TB | Tray 06 β Lower | Mirror 06 | Data | x | |
| D12 | S1YKNX0H602510 | PM863 | 1.92 TB | Tray 06 β Lower | Mirror 06 | Data | x | |
| D13 | 2967 | PM863 | 1.92 TB | Tray 07 β Lower | Mirror 07 | Data | drive-scsi3 | |
| D14 | 4440 | PM863 | 1.92 TB | Tray 07 β Lower | Mirror 07 | Data | drive-scsi8 | |
| D15 | 2516 | PM863 | 1.92 TB | Tray 08 β Lower | Mirror 08 | Data | ||
| D16 | 1375 | PM863 | 1.92 TB | Tray 08 β Lower | Mirror 08 | Data | ||
| D17 | 9974 | PM863 | 1.92 TB | Tray 09 β Rear | Mirror 09 | Data | ||
| D18 | 2518 | PM863 | 1.92 TB | Tray 09 β Rear | Mirror 09 | Data | ||
| D19 | 1430 | PM863 | 1.92 TB | Tray 10 β Rear | Mirror 10 | Data | ||
| D20 | 5670 | PM863 | 1.92 TB | Tray 10 β Rear | Mirror 10 | Data | ||
| D21 | 2714 | PM863 | 1.92 TB | Behind Motherboard | Mirror 11 | Data | ||
| D22 | 4477 | PM863 | 1.92 TB | Behind Motherboard | Mirror 11 | Data |
π§© VDEV Layout Map
Each tray houses two drives which form a mirrored vdev.
- Mirror 01 β D01 + D02
- Mirror 02 β D03 + D04
- Mirror 03 β D05 + D06
- Mirror 04 β D07 + D08
- Mirror 05 β D09 + D10
- Mirror 06 β D11 + D12
- Mirror 07 β D13 + D14
- Mirror 08 β D15 + D16
- Mirror 09 β D17 + D18
- Mirror 10 β D19 + D20
- Mirror 11 β D21 + D22
Total Usable Capacity: ~21 TB Flash Total Drives: 22 VDEV Count: 11 mirrored pairs
πΊ Physical Placement Diagram
This helps identify drives quickly without opening trays or following cables manually.
Front Drive Stack (Upper Section)
- Tray 01 β D01, D02
- Tray 02 β D03, D04
- Tray 03 β D05, D06
- Tray 04 β D07, D08
- Tray 05 β D09, D10
Front Drive Stack (Lower Section)
- Tray 06 β D11, D12
- Tray 07 β D13, D14
- Tray 08 β D15, D16
Rear / PSU Shroud / Inline Mount Areas
- Tray 09 β D17, D18
- Tray 10 β D19, D20
Behind Motherboard / Cable Channel
- Inline β D21, D22
π Port Mapping (To Fill In)
Document the exact SATA/SAS/HBA port numbers for future replacements.
| Drive ID | Controller | Port Number | Notes |
| βββ- | ββββ- | βββββ | βββ |
| D01 | SATA | ||
| D02 | SATA | ||
| D03 | SATA | ||
| D04 | SATA | ||
| D05 | HBA1 | Port X | |
| D06 | HBA1 | Port X | |
| D07 | HBA1 | Port X | |
| D08 | HBA1 | Port X | |
| D09 | HBA1 | Port X | |
| D10 | HBA1 | Port X | |
| D11 | HBA2 | Port X | |
| D12 | HBA2 | Port X | |
| D13 | HBA2 | Port X | |
| D14 | HBA2 | Port X | |
| D15 | HBA2 | Port X | |
| D16 | HBA2 | Port X | |
| D17 | HBA2 | Port X | |
| D18 | HBA2 | Port X | |
| D19 | SATA | Port X | |
| D20 | SATA | Port X | |
| D21 | SATA | Port X | |
| D22 | SATA | Port X |
π§ͺ Burn-In Checklist (Optional but Recommended)
For each drive (D01βD22):
- [ ] SMART extended test
- [ ] Write/verify test
- [ ] Check power-on hours
- [ ] Check wear level
- [ ] Confirm firmware
- [ ] Confirm TrueNAS recognizes it
- [ ] Assign to correct vdev
- [ ] Update this page
π Replacement Procedure
1. Identify failing drive from TrueNAS alert 2. Locate drive in this table 3. Check physical tray for that ID 4. Power down host 5. Remove SSD from its tray / stack 6. Insert replacement drive and label it 7. Update wiki entry 8. Online replace the disk in TrueNAS 9. Verify resilver 10. Mark task completed
π Notes
*All SSDs are Samsung PM863 enterprise-grade SATA 1.92 TB drives salvaged from Nimble arrays.* *All vdevs are mirrors for maximum IOPS, redundancy, and resilver performance.*