User Tools

Site Tools


hardware:flash-array

TorresVault Flash Array (SSD Pool)

This page documents the full SSD layout, serial numbers, physical placement, and ZFS vdev assignments for the all-flash array inside the PVE-NAS node.

This array uses 22 Γ— Samsung PM863 1.92TB SSDs arranged as 11 mirrored vdevs.


πŸ“¦ Drive Inventory – Master Table

ID Serial Number Model Size Port Mapping Physical Location VDEV Role Notes
—– β€”β€”β€”β€”β€”- ——– ——– —————– β€”β€”β€”β€”β€”β€”β€”β€”- ——– ——– ——–
D01 S1YKNX0H602526 PM863 1.92 TB Tray 01 – Upper Mirror 01 Data
D02 S1YKNXAGB51740 PM863 1.92 TB Tray 01 – Upper Mirror 01 Data drive-scsi3
D03 S1YKNXAH301378 PM863 1.92 TB Tray 02 – Upper Mirror 02 Data drive-scsi6
D04 S1YKNXAGB49810 PM863 1.92 TB Tray 02 – Upper Mirror 02 Data
D05 S1YKNX0H602529 PM863 1.92 TB Tray 03 – Upper Mirror 03 Data
D06 S1YKNXAGB55937 PM863 1.92 TB Tray 03 – Upper Mirror 03 Data X
D07 bf9b PM863 1.92 TB Tray 04 – Upper Mirror 04 Data
D08 5e8c PM863 1.92 TB Tray 04 – Upper Mirror 04 Data
D09 S1YKNXAH301436 PM863 1.92 TB Tray 05 – Upper Mirror 05 Data x
D10 S1YKNXAGB51503 PM863 1.92 TB Tray 05 – Upper Mirror 05 Data x
D11 S1YKNXAGB52794 PM863 1.92 TB Tray 06 – Lower Mirror 06 Data x
D12 S1YKNX0H602510 PM863 1.92 TB Tray 06 – Lower Mirror 06 Data x
D13 2967 PM863 1.92 TB Tray 07 – Lower Mirror 07 Data drive-scsi3
D14 4440 PM863 1.92 TB Tray 07 – Lower Mirror 07 Data drive-scsi8
D15 2516 PM863 1.92 TB Tray 08 – Lower Mirror 08 Data
D16 1375 PM863 1.92 TB Tray 08 – Lower Mirror 08 Data
D17 9974 PM863 1.92 TB Tray 09 – Rear Mirror 09 Data
D18 2518 PM863 1.92 TB Tray 09 – Rear Mirror 09 Data
D19 1430 PM863 1.92 TB Tray 10 – Rear Mirror 10 Data
D20 5670 PM863 1.92 TB Tray 10 – Rear Mirror 10 Data
D21 2714 PM863 1.92 TB Behind Motherboard Mirror 11 Data
D22 4477 PM863 1.92 TB Behind Motherboard Mirror 11 Data

🧩 VDEV Layout Map

Each tray houses two drives which form a mirrored vdev.

  • Mirror 01 β†’ D01 + D02
  • Mirror 02 β†’ D03 + D04
  • Mirror 03 β†’ D05 + D06
  • Mirror 04 β†’ D07 + D08
  • Mirror 05 β†’ D09 + D10
  • Mirror 06 β†’ D11 + D12
  • Mirror 07 β†’ D13 + D14
  • Mirror 08 β†’ D15 + D16
  • Mirror 09 β†’ D17 + D18
  • Mirror 10 β†’ D19 + D20
  • Mirror 11 β†’ D21 + D22

Total Usable Capacity: ~21 TB Flash Total Drives: 22 VDEV Count: 11 mirrored pairs


πŸ—Ί Physical Placement Diagram

This helps identify drives quickly without opening trays or following cables manually.

Front Drive Stack (Upper Section)

  • Tray 01 β†’ D01, D02
  • Tray 02 β†’ D03, D04
  • Tray 03 β†’ D05, D06
  • Tray 04 β†’ D07, D08
  • Tray 05 β†’ D09, D10

Front Drive Stack (Lower Section)

  • Tray 06 β†’ D11, D12
  • Tray 07 β†’ D13, D14
  • Tray 08 β†’ D15, D16

Rear / PSU Shroud / Inline Mount Areas

  • Tray 09 β†’ D17, D18
  • Tray 10 β†’ D19, D20

Behind Motherboard / Cable Channel

  • Inline β†’ D21, D22

πŸ”Œ Port Mapping (To Fill In)

Document the exact SATA/SAS/HBA port numbers for future replacements.

Drive ID Controller Port Number Notes
β€”β€”β€”- β€”β€”β€”β€”- ————– ——–
D01 SATA
D02 SATA
D03 SATA
D04 SATA
D05 HBA1 Port X
D06 HBA1 Port X
D07 HBA1 Port X
D08 HBA1 Port X
D09 HBA1 Port X
D10 HBA1 Port X
D11 HBA2 Port X
D12 HBA2 Port X
D13 HBA2 Port X
D14 HBA2 Port X
D15 HBA2 Port X
D16 HBA2 Port X
D17 HBA2 Port X
D18 HBA2 Port X
D19 SATA Port X
D20 SATA Port X
D21 SATA Port X
D22 SATA Port X

For each drive (D01–D22):

  • [ ] SMART extended test
  • [ ] Write/verify test
  • [ ] Check power-on hours
  • [ ] Check wear level
  • [ ] Confirm firmware
  • [ ] Confirm TrueNAS recognizes it
  • [ ] Assign to correct vdev
  • [ ] Update this page

πŸ“ Replacement Procedure

1. Identify failing drive from TrueNAS alert 2. Locate drive in this table 3. Check physical tray for that ID 4. Power down host 5. Remove SSD from its tray / stack 6. Insert replacement drive and label it 7. Update wiki entry 8. Online replace the disk in TrueNAS 9. Verify resilver 10. Mark task completed


πŸ“š Notes

*All SSDs are Samsung PM863 enterprise-grade SATA 1.92 TB drives salvaged from Nimble arrays.* *All vdevs are mirrors for maximum IOPS, redundancy, and resilver performance.*

hardware/flash-array.txt Β· Last modified: by 192.168.1.189

Donate Powered by PHP Valid HTML5 Valid CSS Driven by DokuWiki